Last Modified: 11-29-2007 |
1.6 C |
|
Service Category: Drivetrain |
Section: Automatic Transmission/Transaxle |
|
Model Year: 2008 |
Model: Sequoia |
Doc ID: RM000000W89045X |
|
Title: A750F AUTOMATIC TRANSMISSION / TRANSAXLE: AUTOMATIC TRANSMISSION SYSTEM: DESCRIPTION (2008 Sequoia) |
|
DTC
|
P2759
|
Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU)
|
DESCRIPTION
The amount of current flow to the solenoid is controlled by the duty ratio* of the ECM output signal. During the lock-up operation, if the duty ratio increases, the lock-up hydraulic pressure increases.
HINT:
*: The duty ratio is the ratio of the current ON time (A) to the total of the current ON and OFF time (A + B). Duty Ratio (%) = A / (A + B) x 100
|
DTC No.
|
DTC Detection Condition
|
Trouble Area
|
|
P2759
|
Open or short is detected in shift solenoid valve SLU circuit for 1 second or more while driving (1-trip detection logic).
|
-
Open or short in shift solenoid valve SLU circuit
-
Shift solenoid valve SLU
-
ECM
|
MONITOR DESCRIPTION
When an open or short in a shift solenoid valve (SLU) circuit is detected, the ECM determines there is a malfunction. The ECM will turn on the MIL and store this DTC.
MONITOR STRATEGY
|
Related DTCs
|
P2759: Shift solenoid valve SLU/Range check
|
|
Required sensors/Components
|
Shift solenoid valve SLU
|
|
Frequency of operation
|
Continuous
|
|
Duration
|
1 second
|
|
MIL operation
|
Immediately
|
|
Sequence of operation
|
None
|
TYPICAL ENABLING CONDITIONS
All
|
The monitor will run whenever the following DTCs are not present
|
None
|
All of the following conditions are met: Condition (A) and (B)
Condition (A)
|
Solenoid current cut status
|
Not cut
|
|
Battery voltage
|
11 V or more
|
|
Ignition switch
|
ON
|
|
Starter
|
OFF
|
Condition (B)
|
Battery voltage
|
8 V or more
|
|
Ignition switch
|
ON
|
|
Starter
|
OFF
|
TYPICAL MALFUNCTION THRESHOLDS
When either condition below is met: Condition (A) or (B)
Condition (A)
|
Solenoid status from hybrid IC
|
Failure (open or short)
|
Condition (B)
COMPONENT OPERATING RANGE
|
Output signal duty
|
Less than 100%
|
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
|
1.
|
INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLU)
|
|
(a) Disconnect the D41 transmission wire connector.
|
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
|
Tester Connection
|
Condition
|
Specified Condition
|
|
13 (SLU+) - 5 (SLU-)
|
20°C (68°F)
|
5.0 to 5.6 Ω
|
|
13 (SLU+) - Body ground
|
Always
|
10 kΩ or higher
|
|
5 (SLU-) - Body ground
|
Always
|
10 kΩ or higher
|
| OK |
|
|
|
2.
|
CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
|
|
(a) Disconnect the D56 ECM connector.
|
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
|
Tester Connection
|
Condition
|
Specified Condition
|
|
D56-10 (SLU+) - D56-11 (SLU-)
|
20°C (68°F)
|
5.0 to 5.6 Ω
|
|
D56-10 (SLU+) - Body ground
|
Always
|
10 kΩ or higher
|
|
D56-11 (SLU-) - Body ground
|
Always
|
10 kΩ or higher
|
| OK |
|
|
|
3.
|
INSPECT SHIFT SOLENOID VALVE SLU
|
|
(a) Remove the shift solenoid valve SLU.
|
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
|
Tester Connection
|
Condition
|
Specified Condition
|
|
1 - 2
|
20°C (68°F)
|
5.0 to 5.6 Ω
|
(c) Connect the battery positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.
OK:
Valve moves and makes an operating noise.
| OK |
|
|
|